There is no destination memory for copying the finished image.

Possible cause/remedy: Not enough destination memory allocated or all destination buffers locked by the application.

Release locked destination memory

Allocate more destination memory

Reduce the frame rate so that there is more time to process the filled destination memory

Name

StreamCapStatusAPINoDestMem

Category

StreamCaptureStatus

Interface

Integer

Access

Read

Unit

-

Visibility

Expert

Values

0 … 4294967295