IDS Peak comfortSDK, genericSDK, IPL, and AFL developer manuals are external documents. Please contact us if you need them.
Freerun mode: The camera could neither process nor output an image captured by the sensor.
Hardware trigger mode: The camera received a hardware trigger signal which could not be processed because the sensor was still busy.
Possible cause/remedy: The camera's frame rate is too high or the bandwidth on the network is insufficient to transfer the image
•Check the host performance (see uEye Cockpit: Performance overview or uEye Demo: Performance information).
•Reduce the frame rate
•GigE uEye cameras: Increase the value for the receive descriptors in the network card settings
Name |
StreamCapStatusDevMissedImages |
Category |
|
Interface |
Integer |
Access |
Read |
Unit |
- |
Visibility |
Expert |
Values |
0 … 4294967295 Increment: 1 |
Standard |
IDS |
Availability uEye+ |
- |
Availability uEye |
|