Navigation: D: Specifications > GigE uEye FA > Optical specifications GigE uEye FA

Position accuracy of the sensor GigE uEye FA

Scroll Previous Top Next More

The following illustrations show the tolerance margins of the sensor position relative to the outer camera front. A maximum error in all directions (rotation, translation) cannot occur at the same time.

Fig. 587: Position accuracy of the sensor (1)

Fig. 587: Position accuracy of the sensor (1)

Fig. 588: Position accuracy of the sensor (2)

Fig. 588: Position accuracy of the sensor (2)

It cannot be guaranteed that the sensor cover glass or filter glass are absolutely parallel to each other.

hint_info

C-mount lenses can also be subject to inaccuracies of the flange back distance. The tolerance usually is ±0.05 mm. In some cases, however, the inaccuracies of camera and lens might add up, resulting in a total error > 0.05 mm.

Position accuracy, in each direction

±0.3 mm

Horizontal/vertical rotation (α)

±1.0°

Tilt (β)

±1.0°

Flange back distance

±0.05 mm