Please enable JavaScript to view this site.

IDS peak 2.10.0 / uEye+ firmware 3.34

IDS Peak comfortSDK, genericSDK, IPL, and AFL developer manuals are external documents. Please contact us if you need them.

Minimum limit of the exposure time when ExposureAuto is enabled and BrightnessAutoExposureTimeLimitMode is "On".

hint_info

It is recommended to keep BrightnessAutoExposureTimeMin on its minimum value.

Name

BrightnessAutoExposureTimeMin

Category

BrightnessAutoControl

Interface

Float

Access

Read/Write

Unit

µs

Visibility

Expert

Values

≥ 0

Standard

IDS

Availability uEye+

icon-gev icon-u3v

Availability uEye

-

Code example

C++

// Before accessing BrightnessAutoExposureTimeMin, make sure BrightnessAutoExposureTimeLimitMode is set correctly
// Set BrightnessAutoExposureTimeLimitMode to "On"
nodeMapRemoteDevice->FindNode<peak::core::nodes::EnumerationNode>("BrightnessAutoExposureTimeLimitMode")->SetCurrentEntry("On");
// Determine the current BrightnessAutoExposureTimeMin
double value = nodeMapRemoteDevice->FindNode<peak::core::nodes::FloatNode>("BrightnessAutoExposureTimeMin")->Value();
// Set BrightnessAutoExposureTimeMin to 25.1 us
nodeMapRemoteDevice->FindNode<peak::core::nodes::FloatNode>("BrightnessAutoExposureTimeMin")->SetValue(25.1);

C#

// Before accessing BrightnessAutoExposureTimeMin, make sure BrightnessAutoExposureTimeLimitMode is set correctly
// Set BrightnessAutoExposureTimeLimitMode to "On"
nodeMapRemoteDevice.FindNode<peak.core.nodes.EnumerationNode>("BrightnessAutoExposureTimeLimitMode").SetCurrentEntry("On");
// Determine the current BrightnessAutoExposureTimeMin
double value = nodeMapRemoteDevice.FindNode<peak.core.nodes.FloatNode>("BrightnessAutoExposureTimeMin").Value();
// Set BrightnessAutoExposureTimeMin to 25.1 us
nodeMapRemoteDevice.FindNode<peak.core.nodes.FloatNode>("BrightnessAutoExposureTimeMin").SetValue(25.1);

Python

# Before accessing BrightnessAutoExposureTimeMin, make sure BrightnessAutoExposureTimeLimitMode is set correctly
# Set BrightnessAutoExposureTimeLimitMode to "On" (str)
nodeMapRemoteDevice.FindNode("BrightnessAutoExposureTimeLimitMode").SetCurrentEntry("On")
# Determine the current BrightnessAutoExposureTimeMin (float)
value = nodeMapRemoteDevice.FindNode("BrightnessAutoExposureTimeMin").Value()
# Set BrightnessAutoExposureTimeMin to 25.1 us (float)
nodeMapRemoteDevice.FindNode("BrightnessAutoExposureTimeMin").SetValue(25.1)

© 2024 IDS Imaging Development Systems GmbH