This feature is only supported by specific uEye cameras:

UI-124x/UI-324x/UI-524x

UI-125x/UI-325x/UI-525x

When LogMode is set to "Manual" , no master gain is possible. The gain is adjusted with LogModeManualGain. The gain can be set in 5 levels. Level "3" corresponds to a gain factor of 1 for monochrome or color sensors. Level "1" corresponds to a gain factor of 1 for NIR sensors.

Example: A low level results in a low gain setting and may display more details in overexposed image details. A higher level results in a higher gain setting and thus a darker image can be brightened.

LogModeManualGain is active when LogMode is set to "Manual".

Name

LogModeManualGain

Category

AnalogControl

Interface

Integer

Access

Read/Write

Unit

-

Visibility

Expert

Values

Camera specific