Please enable JavaScript to view this site.

IDS Software Suite 4.96.1

8-pin Hirose connector (HR25-7TR-8PA(73))

Pin

Description

Fig. 563: GigE uEye CP Rev. 2, Hirose connector male, camera rear view

Fig. 563: GigE uEye CP Rev. 2, Hirose connector male, camera rear view

1

Ground (GND)

2

Flash output with optocoupler (-)

3

General purpose I/O (GPIO) 1, 3.1 V

4

Trigger input with optocoupler (-)

5

Flash output with optocoupler (+)

6

General purpose I/O (GPIO) 2, 3.1 V

7

Trigger input with optocoupler (+)

8

Input power supply (VCC) 12-24 V DC

You can check the color assignment of the cable on the Website directly at the specific accessory item.

hint_info

The maximum length of the I/O cable is 30 m. The cable must be shielded.

Power supply

Voltage

Tolerance

Residual ripple

12-24 V

+/- 10 %

max. 120 mVpp

IDS Imaging Development Systems GmbH recommends to adjust the power supply to the power requirement of the camera to limit overheating in case of short circuit.

To ensure the electrical safety, the camera power supply must meet the requirements for SELV (safety extra low voltage) / LPS (limited power source) or ES1 / PS2. The camera power supply must be rated by the values given in the table above. It also must ensure that the voltage values given in the table above are available at the input of the camera.


Avis pour le Canada:
IDS Imaging Development Systems GmbH recommande d'adapter l'alimentation électrique aux besoins de la caméra afin de limiter la surchauffe en cas de court-circuit.

Pour garantir la sécurité électrique, l'alimentation de la caméra doit être conforme aux exigences de sécurité SELV (très basse tension de sécurité)/LPS (source à puissance limitée) ou ES1/PS2. L'alimentation de la caméra doit respecter les valeurs indiquées dans le tableau ci-dessus. Elle doit également répondre au fait que les tensions indiquées dans le tableau ci-dessus sont présentes à l'entrée de la caméra.


Information on the power consumption of individual camera models can be found in the model data sheet.

hint_notice

NOTICE! The camera can be supplied with voltage both from an external source and via Power-over-Ethernet (PoE). The camera should not be supplied through both voltage sources at once as this can irreparably damage the camera.

hint_info

Keep in mind that a voltage drop will occur when you use long cables for power supply to the camera. Choose the size of the cable in such a way that the supply voltage available at the input of the camera is at least 12 V.

hint_info

To supply the uEye camera with power using PoE or PoE+, you can use PoE injectors or switches that are compatible with IEEE standard 802.3af or IEEE standard 802.at.

The cameras register to the PoE class 2 (3.84-6.49 W). Depending on the operating mode, a camera can also consume less than 3.84 W.