Please enable JavaScript to view this site.

IDS Software Suite 4.96.1

hint_notice

NOTICE! The General Purpose I/Os are not potential-free and have no protective circuit. Faulty wiring (overvoltage, undervoltage or inverting the wiring when used as serial interface) can result in a damage in the electronics.

During operation as serial interface only LVCMOS levels are allowed to the connector pins. To get a serial RS-232 compliant interface, an external level shifter (LVCMOS/RS-232) is required.

Applying RS-232 levels directly to the pins as well as mixing up the signals RxD and TxD can destroy the camera electronics!

8-pin Hirose connector (HR25-7TR-8PA(73))

Pin

Description

Fig. 441: USB 3 uEye ML, Hirose connector male, camera rear view

Fig. 441: USB 3 uEye ML, Hirose connector male, camera rear view

1

Ground (GND)

2

Flash output with optocoupler (-)

3

General purpose I/O (GPIO) 1, 3.3 V

4

Trigger input with optocoupler (-)

5

Flash output with optocoupler (+)

6

General purpose I/O (GPIO) 2, 3.3 V

7

Trigger input with optocoupler (+)

8

Output supply voltage, 5 V (100 mA)

You can check the color assignment of the cable on the Website directly at the specific accessory item.

hint_info

The maximum length of the I/O cable is 30 m. The cable must be shielded.

Power supply

The camera is supplied with power via the USB 3.0 interface. For information on the camera's power consumption, please refer to the Camera and sensor data section.

© 2022 IDS Imaging Development Systems GmbH