Please enable JavaScript to view this site.

IDS Software Suite 4.96.1

hint_notice

NOTICE! The General Purpose I/Os are not potential-free and have no protective circuit. Faulty wiring (overvoltage, undervoltage or inverting the wiring when used as serial interface) can result in a damage in the electronics.

During operation as serial interface only LVCMOS levels are allowed to the connector pins. To get a serial RS-232 compliant interface, an external level shifter (LVCMOS/RS-232) is required.

Applying RS-232 levels directly to the pins as well as mixing up the signals RxD and TxD can destroy the camera electronics!

Serial interface specification

Minimum output voltage

 

Min.

Max.

 

Signal level "Low"

0

0.8

V

Signal level "High"

2.0

4.0

V

Maximum input voltage

 

Min.

Max.

 

Signal level "Low"

0

0.8

V

Signal level "High"

2.0

4.0

V

Supported Baud rates

9.600

19.200

38.400

57.600

115.200

baud

Transmission mode

Full duplex, 8N1

 

Data bits

8

 

Stop bits

1

 

Parity

None

 

hint_info

With the 8N1 mode, the maximum payload data rate achievable is 80% of the selected baud rate.

Serial interface wiring (UART)

The following figure shows the wiring of the serial interface with GPIO 1 as camera-side output (TxD) and GPIO 2 as camera-side input (RxD). The GPIO must be configured accordingly (see is_IO()).

Fig. 448: Serial interface connector (UART)

Fig. 448: Serial interface connector (UART)

Serial interface wiring (RS-232)

Fig. 449: Serial interface connector (RS-232)

Fig. 449: Serial interface connector (RS-232)

© 2022 IDS Imaging Development Systems GmbH