NOTICE! The General Purpose I/Os are not potential-free and have no protective circuit. Faulty wiring (overvoltage, undervoltage) can result in a damage in the electronics. |
8-pin Hirose connector (HR25-7TR-8PA(73))
Pin |
Description |
Fig. 363: Hirose connector male, camera rear view |
---|---|---|
1 |
Ground (GND) |
|
2 |
Flash output with optocoupler (-) |
|
3 |
General Purpose I/O (GPIO) 1, 3.3 V |
|
4 |
Trigger input with optocoupler (-) |
|
5 |
Flash output with optocoupler (+) |
|
6 |
General Purpose I/O (GPIO) 2, 3.3 V |
|
7 |
Trigger input with optocoupler (+) |
|
8 |
Voltage output •Without USB Power Delivery: 5 V, max. 100 mA •With USB Power Delivery: 5 – 15 V, max. 1 A |
You can check the color assignment of the cable on the Website directly at the specific accessory item.
The maximum length of the I/O cable is 30 m. The cable must be shielded. |
Power supply
The camera is supplied with power via the USB 3.0 interface. For information on the camera's power consumption, please refer to the Camera and sensor data section.
Note on Power Delivery
There are only the voltages available on the camera that are offered by the host PC. If you switch from a higher voltage to a lower voltage during operation, the camera will do a reconnect.