This chapter contains the descriptions of all supported features from the Sequencer Control category.

Name

Sequencer Control

Category

Root

Interface

Category

Access

Read

Unit

-

Visibility

Expert

Values

-

Standard

SFNC

Availability uEye+

icon-gev icon-u3v

Availability uEye

-

Use the sequencer to change some features of the camera automatically based on different events and signals.

Activate the SequencerConfigurationMode to create or modify a sequencer set.

Configure a sequencer set

Select a sequencer set via SequencerSetSelector.

A next sequencer set, that should follow the previous sequencer set is defined via SequencerSetNext. Use SequencerPathSelector and SequencerTriggerSource to define the events that result in a change from one sequencer set to another.

Have a look at the SequencerTriggerActivation.

Use the SequencerFeatureSelector to define which features should be adjustable in your sequencer sets.

Save the sequencer set via SequencerSetSave.

Modify a sequencer set

Select a sequencer set with SequencerSetSelector.

Load the setting from this sequencer set with SequencerSetLoad.

Make your changes in selected sequencer set.

Save the changed sequencer set via SequencerSetSave.

Use SequencerMode to activate the sequencer.